| Set point range: |
AT1_: 0.04 to 3 fps
(0.012 to 0.91 mps)
AG1_: 1 to 90 fps (0.3 to 27 mps) |
| Factory set point: |
AT1_: 0.2 fps (0.06 mps)
AG1_: 10 fps (3 mps) |
| Repeatability: |
±.5% of set point |
| Response time: |
1-10 seconds |
| Set point adjust.: |
Potentiometer |
| Viscosity range: |
AT1_: 1-200 centipoise
AG1_: N/A |
| Supply voltage: |
120/240 VAC @ 50-60 Hz. |
| Contact type: |
(1) SPDT relay |
| Contact rating: |
250 VAC @ 10A |
| Contact delay: |
0-60 seconds |
| LED indication: |
Power, relay and sensor status |
| Strobe type: |
_61_: Xenon tube
_62_: N/A |
| Strobe flash: |
_61_: 1 per second
_62_: N/A |
| Process temp.: |
F: 32° to 140°
C: 0° to 60° |
| Electronics temp.: |
F: -40° to 140°
C: -40° to 60° |
| Pressure: |
150 psi (10 bar) @ 25° C.,
derated @ 1.667 psi (0.113 bar)
per ÝC. above 25° C. |
| Wetted material: |
16__: PP-Ryton®
36__: PVDF Kynar® |
| Process mount: |
3/4" NPT (3/4" G) |
| Mount. gasket: |
Viton® (G version only) |
| Enclosure rating: |
NEMA 4X (IP65) |
| Encl. material: |
_61_: PP, UL94VO and polycarbonate
_62_: PP, UL94VO |
| Conduit entrance: |
Single, 1/2" NPT |
| Classification: |
General purpose |
| CE compliance: |
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety |