CHEM-GARD, Horizontal Centrifugal Pumps

Differential Pressure Gauges - Sensocon Series S2000

Series S2000 Mechanical Differential Pressure Gauges

Series S2000

The Series S2000 is a low cost, diaphragm operated, differential pressure gauge. The S2000 can be used in applications for measuring positive, negative, or differential pressure with an accuracy of 2%. Standard applications include monitoring filter status, duct static pressure, room pressure, fan or blower pressure, paint booths, dust collectors, and cabinet purging along with many others.

Data Sheet PDF
Installation Manual PDF

Specifications

Pressure Limits:
-20" Hg to 15 PSI (-0.677 bar to 1.034 bar); MP option: 35 PSI (2.41 bar)
Media compatibility:
Air and compatible gasses
Accuracy:
+/- 2% full scale (+/- 3% on -0 and +/- 4% on -00) throughout range at 70°F (21°C)
Temperature Ranges:
20° to 140°F (-7° to 60°C)
Housing Material:
Die cast aluminum case and bezel, with acrylic cover
Process Connection:
1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back.
Weight:
1 lb 2 oz (510 g), MP & HP 2 lb 2 oz (963 g)
Accessories:
Two 1/8" NPT barbed fittings, two 1/8" NPT plugs, and three mounting tabs and screws
Dimensional Drawing

series S2000 - Dimesional Drawing

Model Numbers

Model Number
Pressure Range
 
Model Number
Pressure Range
S2000-00
0 - 0.25"
 
S2020
0 - 20"
S2000-0
0 - 0.5"
 
S2025
0 - 25"
S2001
0 - 1"
 
S2030
0 - 30"
S2002
0 - 2"
 
S2050
0 - 50"
S2003
0 - 3"
 
S2100
0 - 100"
S2004
0 - 4"
 
S2300-0
0.25 - 0 - 0.25"
S2005
0 - 5"
 
S2301
0.5 - 0 - 0.5"
S2006
0 - 6"
 
S2302
1 - 0 - 1"
S2008
0 - 8"
 
S2304
2 - 0 - 2"
S2010
0 - 10"
 
S2310
5 - 0 - 5"
S2015
0 - 15"
 
S2320
10 - 0 - 10"

*Other pressure ranges available upon request.



See More Sensocon Differential Pressure Gauges

Series A1
Digital differential pressure gauge with full scale ranges as low as 0.5" up to 30" w.c., 1% or 0.5% accuracy, and optional 4-20 mA output.
Series A2
Digital differential pressure gauge with Process Arch, full scale ranges as low as 0.5" up to 30" w.c., 1% or 0.5% accuracy, and optional 4-20 mA output.
Series A3
Digital differential pressure controller with Process Arch and LCD programming display, full scale ranges as low as 0.5" up to 30" w.c., 1% or 0.5% accuracy, and optional 4-20 mA output.
Series A4
Digital differential pressure controller with Process Arch and OLED programming display, full scale ranges as low as 0.5" up to 30" w.c., 1% or 0.5% accuracy, and optional 4-20 mA output.
Series 211
The Series 211 Differential pressure transmitter with pressure ranges from 1” w.c. up to 15 PSI with 0.25% accuracy.
Opti-Link
OptiLink™ Programming Keys

For More Product Information
Or Call: 905 - 669 - 4857

Click Logo To Visit

Click on the logo to visit Company Product Sites on the
Process Controls and Instrumentation web site.


If It's New You'll Find It In Process News!

Designed By Panther Marketing & Design