460

|
The
460 hand held oscilloscope features a 3" x 3"
cold cathode fluorescent display providing test data
in a clear easy to see format. The cursor readout
function allows the width and amplitude of a signal
to be measured precisely instead of trying to figure
it out manually.
- 4,000 count true
RMS DMM, CACV, DCV ohms and continuity buzzer
need optional adapters for current measurement
- 20 MHz Bandwidth
- Cursor Readout
- Decibels
- Pre and Post Triggering
- Trend Mode
- Dual Input
- Real Time Sample
Rate
- Bright LCD Backlight
- Optically Isolated
RS232 Output
- Continuous Autoset
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
440

|
The
hand held 440 scope plus features an easy to use combination
of a single input 1 MHz oscilloscope with True RMS
DMM.
- True RMS Auto
Ranging DMM offers increased accuracy over average
responding multimeters
- 1MHz Oscilloscope
can be used to view power signals to determine
quality as well as correct amplitude and frequency,
assisting in finding and preventing problems
- Trend Mode enables
surges and dropouts to be graphed.
- Communication
to a PC using optional RS-232 cable and software
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
196

|
0-24
mA output built in for process loop calibration, 0.05%
accuracy, 50,000 counts, DMM with separate fuse and
battery compartment
- Process DMM with
0 to 24mA output
- 50,000 count display
- 0.05% DCV basic
accuracy
- 0 to 750 ACV;
max resolution 100uV
- 0 to 1,000 DCV;
max resolution 0.001mV
- 0 to 50MΩ;
max resolution 0.01Ω
- Audible continuity
- AC/DC amps up
to10 amps; max resolution 0.01uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse
and battery compartment
- cULus 61010-1
- CAT II-1000VDC,
750VAC, CATIII-600V
- Limited Life time
Warranty
|
Product
Sheet
nstruction
Manual

|
| |
|
|
194

|
CAT
IV 600 ACV, data logging, 0.05% accuracy, 50,000 count,
True RMS DMM with separate fuse and battery compartment
- Data logging
- 50,000 count display
- 0.05% DCV basic
accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV;
max resolution 100uV
- 0 to 1,000 DCV:
max resolution 0.001mV
- 0 to 50MΩ
max resolution 0.01Ω
- Audible continuity
- AC/DC amps up
to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse
and battery compartment
- cULus 61010-1
- CATIII-1000VC,
CATIII-1000V, CAT IV-600V, CAT III 1000V
- Limited Life time
Warranty
|
Data
Sheet
Instruction
Manual

|
| |
|
|
192

|
Data
logging, 0.05% accuracy, 50,000 count, True RMS DMM
with separate fuse and battery compartment.
- Data logging
- 50,000 count display
- 0.05% DCV basic
accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV;
max resolution 100uV
- 0 to 1,000 DCV:
max resolution 0.001mV
- 0 to 50MΩ
max resolution 0.01Ω
- Audible continuity
- AC/DC amps up
to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse
and battery compartment
- cULus 61010-1
- CAT II-1000VDC,
750VAC, CAT III - 600V
- Limited Life time
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
183A

|
True
RMS DMM with temperature, capacitance, duty cycle,
& low-pass filter
4,000
count
True
RMS for more accurate measurements
Auto/manual
ranging
Temperature
measurement
Duty
cycle to measure the amount of time the motor is
on
Low
pass filter for noisy environments
Separate
fuse (2) and battery compartment
Auto
power off
IR
serial interface
cULus
61010-1
CAT
II - 1000V, CAT III - 600V
3
Year Limited Warranty
Applications
Test
run and start capacitors
Measure
ambient and duct temp.
Test
control (thermostat, thermocouple, flame safety)
and line voltages
Measure
resistance and test for continuity
Line
current up to 10 amps (in series)
|
Data Sheet
Instruction
Manual

|
| |
|
|
163

|
Full
size DMM with analog bar graph; 1,000 DC volts and
750 AC volts; 0.5% DCV basic accuracy
- 3260 count display
- 0.5% DCV basic
accuracy
- 0 to 750 ACV;
max resolution 1mV
- 0 to 1,000 DCV;
max resolution 0.1mV
- 0 to 32.6MΩ
max resolution 0.1Ω
- Audible continuity
- 0 to 10 amps AC/DC;
max resolution 0.1uA
- Analog bar graph
- Data hold
- Sleep mode/auto
off
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
153

|
Full
size, autoranging, easy to read, 0.3% DCV basic accuracy
DMM; 1,000 DC volts and 750 AC volts
- 0.3% DCV basic
accuracy
- 0 to 750 ACV;
max resolution 1mV
- 0 to 1,000 DCV:
max resolution 0.1mV
- 0 to 40MΩ
max resolution 0.1Ω
- AC/DC amps to
10; max resolution 0.1uA
- Min/Max
- Data hold
- Sleep mode/auto
off
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
135
|
Full
size DMM with capacitance; 1,000 DC volts and 750
AC volts; 0.5% DCV basic accuracy
- 4,000 count display
- 0.5% DCV basic
accuracy
- 0 to 750 ACV;
max resolution 0.1mV
- 0 to 1,000 DCV;
max resolution 0.1mV
- 0 to 40MΩ
max resolution 0.1Ω
- 0 to 10 amps AC/DC;
0.1uA resolution
- Data hold
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
133
|
Large
easy to read display in full size DMM; 1,000 DC volts
and 750 AC volts; 0.5% DCV basic accuracy
- Large easy to
read 2,000 count display
- 0.5% DCV basic
accuracy
- 0 to 750 ACV;
max resolution 1mV
- 0 to 1,000 DCV;
max resolution 0.1mV
- 0 to 20MΩ
max resolution 0.1Ω
- 0 to 10 amps AC/DC;
max resolution 0.1uA
- Data hold
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
126

|
Compact
autoranging DMM with 0.3% DCV basic accuracy and 400mA
AC/DC range
- 4,000 count display
- 0.3% DCV basic
accuracy
- 0 to 600 volts
AC/DC; max resolution 0.1V
- 0 to 40MΩ
resistance; max resolution 0.1Ω
- Audible continuity
- 0 to 400 mA amps
AC/DC; max resolution 0.01mA
- Autoranging
- Min/Max
- Data Hold
- Sleep mode/auto
off
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
122

|
Compact
DMM with adapter range for optional accessories, 0.5%
DCV basic accuracy
- 2,000 mvDC (2
DCV) adapter range
- 2,000 count display
- 0 to 600 volts
AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal
impedance
- 0.5 % DCV basic
accuracy
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
|
120

|
Compact,
manual ranging, basic DCV 0.5% accuracy DMM
- 2,000 count display
- 0 to 600 volts
AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal
impedance
- 0.5% DCV basic
accuracy
- cULus 61010-1
- CAT II - 1000V,
CAT III - 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|
| |
|
|
|
100

|
No
more guessing what range to switch your meter to the
TPI 100 does it automatically!
- Automatically
switches between ACV, DCV, and ohms (resistance).
Benefit Simple to use. Meter selects function
and range, just connect the leads to the device
under test.
- Single button
operation. Benefit EZ to use. Enables users with
limited knowledge to perform tests safely.
- 0 to 600 volts
AC and DC Benefit Enough range to safely perform
measurements
- 10 MΩ
internal impedance. Benefit High impedance prevents
inaccurate reading caused by circuit loading.
- Auto power off.
Benefit Increases battery life by turning off
the multimeter when not in use.
- 4,000 count display
- Up to 40MΩ
- cULus 61010-1
- CAT II 1,000-V
/ CATIII 600V
- 3 Year Limited
Warranty
|
Product
Sheet
Instruction
Manual

|